Boolean sensors and polarity
Prerequisites: electrical signals, Java booleans and the encoder lab. Time: 25 minutes. A digital input reads an electrical logic level; the physical meaning depends on the sensor, wiring and pull-up or pull-down configuration. A normally open switch wired to ground on a pull-up input commonly reads false when pressed, but this is an example, not a universal rule. A break-beam output's polarity likewise depends on its device and wiring. Consult its documentation and verify both states with a mentor before commanding a mechanism.
Interpret a switch
For an explicitly verified active-low input only:
boolean rawHigh = limitSwitch.get(); // DigitalInput; electrical level
boolean pressed = !rawHigh; // this wiring only
This is an excerpt requiring a project-defined DigitalInput, not a complete robot program. For active-high wiring use pressed = rawHigh. Label and log both the raw level and interpreted state. Test switch released and pressed with motors disabled; test an unplugged wire as well because some wiring can appear pressed or unpressed on a fault. A switch reading alone does not prove a mechanism is safe or homed.
Limits and homing
Once polarity and motion direction are confirmed, a reviewed control can prevent movement toward the limit while permitting movement away. Define explicit fail-safe behavior for disconnected, stuck or contradictory switches, and use appropriate independent hardware protections. A switch edge can establish a reference only if it corresponds to a known physical position; account for hysteresis, bounce and repeatability. See zeroing sensors.
Exercise: with active-low wiring, raw true means not pressed and raw false means pressed. Verify this truth table in the encoder lab; change to active-high and predict the result before checking. If the result seems inverted, review wiring and measured voltage before changing software. A pressed limit should inhibit further motion toward it, not necessarily motion away. Source: WPILib digital inputs.